Modbus RTU N
Modbus RTU N is a family of industrial I/O modules for an RS-485 Modbus RTU bus: 8 digital inputs and 8 outputs, 8 analog inputs or 8 analog outputs in the same housing for a 35 mm DIN rail. DC 7…36 V supply with isolated power and RS-485; the address and baud rate are set by a Modbus command. The modules bring status and alarm signals and readings of 4–20 mA and 0–10 V sensors into a SCADA system or BMS and control valves, dampers and variable-frequency drives.
The form failed to load — write to info@orion-m2m.com
Features
- Three module types in the same housing: 8 DI + 8 DO, 8 AI or 8 AO;
- RS-485 Modbus RTU: address 1…255, up to 256,000 bit/s;
- DC 7…36 V supply, isolated power and RS-485;
- Resettable fuse, TVS and reverse-polarity protection;
- AI: 12-bit, current or voltage selectable per channel;
- DO up to 500 mA: DI linkage and pulse modes;
- Applications: status and alarm signals in BMS, 4–20 mA and 0–10 V sensors, valves, dampers, VFD setpoints, I/O expansion over RS-485.
Specifications
General
| Supply voltage, V | DC 7…36 |
|---|---|
| Galvanic isolation | power supply and RS-485 |
| Channel isolation: DI/DO · AI/AO | optical · magnetic |
| Fuse | resettable |
| Protection | TVS, reverse polarity |
| Indicators | RXD, TXD, STATUS; 16 channel LEDs on the DI/DO module |
Communication
| Interface, protocol | RS-485, Modbus RTU (slave) |
|---|---|
| Baud rate, bit/s | 4800…256,000 |
| Factory settings | 9600 bit/s, 8N1, address 1 |
| Parity | none, even, odd |
| Device address | 1…255; 0 for broadcast |
| Function codes, hex: DI/DO · AI · AO | 01 02 03 05 06 0F 10 · 03 04 06 10 · 03 06 10 |
| Line termination, Ω | 120, external |
Construction
| Dimensions with terminals, mm | 72 × 121 × 34 |
|---|---|
| Height without terminals, mm | 102.5 |
| Mounting | 35 mm DIN rail, modules side by side with no gap |
| Wiring | power on the top terminal block, RS-485 on the bottom one; signal terminals on both |
| Address and baud rate setting | by Modbus command (registers 4000 and 2000); no switches on the housing |
Supply
| Scope of delivery | module, product passport, packaging |
|---|---|
| Warranty | 12 months from commissioning, but no more than 18 months from the date of manufacture |
Documentation
Datasheets
Versions
| Part number | Version |
|---|---|
| RTU-N-8DIO | 8 DI 5…36 V: dry contact, NPN, PNP; 8 open-drain DO, 5…36 V, up to 500 mA per channel. |
| RTU-N-8AI | 8 AI: 0–5 / 1–5 V and 0–20 / 4–20 mA, differential or single-ended; 12-bit, accuracy ≤ 3 %, 25 Hz; factory default: current, 0–20 mA. |
| RTU-N-8AI-10 | 8 AI: 0–10 / 2–10 V and 0–20 / 4–20 mA, differential or single-ended; 12-bit, accuracy ≤ 3 %, 25 Hz; factory default: voltage, 0–10 V. |
| RTU-N-8AO-I | 8 AO, current 0–20 mA; 12-bit (1 µA), accuracy ±0.03 mA; 20 mA into a 500 Ω load at a supply of 14 V or more. |
| RTU-N-8AO-U | 8 AO, voltage 0–10 V; 12-bit (1 mV), accuracy ±0.01 V; up to 100 mA per channel. |